Fuel Pump Circuit
- Remove electrical connector from air flow meter. Connect terminals 36 and 39 with jumper wire. Disconnect fuel input line at fuel pressure regulator and place in container. Turn ignition on and push air measuring flap open.
- Fuel should flow into container. If fuel does not flow but clicking sound is heard, replace fuel pump. Fuel circuit is good. If no clicking sound is heard, replace air flow meter assembly and repeat test.