Cranking Test
Connect starting system tester according to manufacturer's instructions. Operate starter. Starter current should not exceed 315 amps. Voltage should not be less than 9 volts.
Connect starting system tester according to manufacturer's instructions. Operate starter. Starter current should not exceed 315 amps. Voltage should not be less than 9 volts.