Starter No-Load Test
Place starter on test bench. Operate starter and ensure voltage, amperage, and RPM are within specification. See STARTER NO-LOAD TEST SPECIFICATIONS table.
STARTER NO-LOAD TEST SPECIFICATIONS
| Application | Volts | Amps | RPM | |
|---|---|---|---|---|
| 9-3 | 12 | 80 | 3300 | |
| 9-5 | ||||
| 4-Cylinder | 12 | 70 | 2550 | |
| 6-Cylinder | 12 | 80 | 2800 | |