Removal Procedure

  1. Remove the negative battery cable. Refer to Battery Negative Cable Replacement (4.2L Engine)  or Battery Negative Cable Replacement (5.3L Engine) .
    Fig 1: Identifying Battery Cable & Current Sensor
    GM1806001Courtesy of GENERAL MOTORS CORP.
  2. Mark the location of the negative battery cable clips and remove the clips from the cable.
  3. Remove the tape securing the generator battery current sensor to the negative battery cable.
  4. Squeeze the negative battery cable branches together.
    IMPORTANT: Note the orientation of the generator battery current sensor prior to removal.
  5. Slide the generator battery current sensor (1) off of the negative battery cable.