Add keys
Before "Add" keys:
Figure 20: CIM, ECM and three keys with a common master key code, illustrated in green. Two of the keys are new and therefore do not have the master key code but all of the keys have different individual key codes.
During "Add" keys:
All keys that shall be used must be on hand when programming starts. The first key programmed must be one of the keys that "belongs" to the CIM that was fitted.
- When carrying out "Add" keys using Tech2, the master key code is copied from CIM to the key. The individual key code is copied from the key to CIM.
- No more than five keys can be programmed to a CIM.
After "Add" keys:
Figure 21: The illustration shows the same CIM, ECM and keys as in Fig 1 . The two new keys are now programmed with the same master key code.