Buzzer On/Off Setting
- Check that the ODO display is on, and turn the ignition switch off and then on. If other display is on, change it to the ODO display.
- Within 2 to 6 seconds after turning the ignition switch ON, push the ODO/TRIP switch and hold it for 10 seconds or more.
- Following the table shown in SET BUZZER CANCEL REFERENCE , set the buzzer cancel setting.SET BUZZER CANCEL REFERENCE
Buzzer Operation Seat belt buzzer for driver's seat Front seat inner belt assay (Driver side) OFF -> ON (Seat belt unfastened -> fastened) HINT:
The ODO/TRIP display changes from "b-on" to "b-off", entering the cancel mode.
- During the cancel mode, each time the ODO/TRIP switch is pushed, the setting is switched between *1
b-on and *2
b-off.
HINT:
*1 b-on: Cancel is invalid
*2 b-off: Cancel is valid
- After the setting, the mode will be canceled by either not operating the switch for 10 seconds or more, or turning the ignition switch from ON to OFF.
HINT:
The setting can be reset when reconnecting the battery connector or removing/installing the meter connector (Buzzer on).