The hand held tester can be used in steps 3, 4, 5, 7 and 10.

  1. VEHICLE BROUGHT TO WORKSHOP 

    NEXT: Go to next step. 

  2. CUSTOMER PROBLEM ANALYSIS (See  CUSTOMER PROBLEM ANALYSIS CHECK   ) 

    NEXT: Go to next step. 

  3. CONNECT HAND HELD TESTER TO DLC3 

    HINT:

    If the display indicates a communication fault in the tester, inspect the DLC3.

    NEXT: Go to next step. 

  4. CHECK DTC AND FREEZE FRAME DATA (SEE  DIAGNOSIS SYSTEM   ) 

    HINT:

    Record or print DTCs and freeze frame data, if necessary.

    NEXT: Go to next step. 

  5. CLEAR DTC AND FREEZE FRAME DATA (SEE  DIAGNOSIS SYSTEM   ) 

    NEXT: Go to next step. 

  6. CONDUCT VISUAL INSPECTION 

    NEXT: Go to next step. 

  7. SET CHECK MODE DIAGNOSIS (SEE  CHECK MODE PROCEDURE   ) 

    NEXT: Go to next step. 

  8. CONFIRM PROBLEM SYMPTOMS 

    HINT:

    If the engine does not start, perform steps  10 and  12 first.

    ENGINE MALFUNCTION REFERENCE

    Result Proceed To
    Malfunction does not occur A
    Malfunction occurs B

    B: Go to step   10 

    A: Go to next step. 

  9. SIMULATE SYMPTOMS 

    NEXT: Go to next step. 

  10. CHECK DTC (SEE  DTC CHECK/CLEAR   ) 
    MALFUNCTION CODE REFERENCE

    Result Proceed To
    Malfunction code A
    No code B

    B: Go to step   12 

    A: Go to next step. 

  11. REFER TO DTC CHART (SEE  DIAGNOSTIC TROUBLE CODE CHART   ) 

    NEXT: Go to step   14 

  12. CONDUCT BASIC INSPECTION (SEE  BASIC INSPECTION   ) 
    MALFUNCTION PART REFERENCE

    Result Proceed To
    Malfunctioning parts not confirmed A
    Malfunctioning parts confirmed B

    B: Go to step   17 

    A: Go to next step. 

  13. REFER TO PROBLEM SYMPTOMS TABLE (SEE  PROBLEM SYMPTOMS TABLE   ) 
    MALFUNCTION CIRCUIT REFERENCE

    Result Proceed To
    Malfunctioning circuit confirmed A
    Malfunctioning parts confirmed B

    B: Go to step   17 

    A: Go to next step. 

  14. CHECK ECM POWER SOURCE CIRCUIT (See  ECM POWER SOURCE CIRCUIT   ) 

    NEXT: Go to next step. 

  15. CONDUCT CIRCUIT INSPECTION 
    CIRCUIT INSPECTION REFERENCE

    Result Proceed To
    Malfunction not confirmed A
    Malfunction confirmed B

    B: Go to step   18 

    A: Go to next step. 

  16. CHECK FOR INTERMITTENT PROBLEMS (SEE  CHECK FOR INTERMITTENT PROBLEMS   ) 

    NEXT: Go to step   18 

  17. CONDUCT PARTS INSPECTION 

    NEXT: Go to next step. 

  18. IDENTIFY PROBLEM 

    NEXT: Go to next step. 

  19. ADJUST AND/OR REPAIR 

    NEXT: Go to next step. 

  20. CONDUCT CONFIRMATION TEST 

    NEXT: END