Mode 6 - 2005 Scion: TC
O2S TEST RESULT
| Test ID | Test Item | Test Value | Unit Conversion | Unit | Standard Value |
|---|---|---|---|---|---|
| $81 | Time $81 | Percentage in monitoring time when HO2S voltage was below 0.05V | Multiply by 0.3906 | % | Within 60 % |
THERMOSTAT TEST RESULT
| Test ID | Test Item | Test Value | Unit Conversion | Unit | Test Limit |
|---|---|---|---|---|---|
| $08 | Thermostat | ECT sensor output when estimated ECT is malfunction threshold | Multiply by 0.625 and minus 40 | °C | Malfunction criteria for thermostat |
A/F SENSOR HEATER MONITOR RESULT
| Test ID | Test Item | Test Value | Unit Conversion | Unit | Test Limit |
|---|---|---|---|---|---|
| $07 | Air-Fuel Ratio (A/F) sensor heater | Maximum A/F sensor heater current | Multiply by 0.173 | A | Malfunction threshold for A/F sensor heater |
O2S HEATER MONITOR RESULT
| Test ID | Test Item | Test Value | Unit Conversion | Unit | Test Limit |
|---|---|---|---|---|---|
| $04 | HO2 sensor heater | Maximum HO2 sensor heater current | Multiply by 0.000076 | A | Malfunction threshold for HO2 sensor heater |
O2S TEST RESULT CHART
| Test ID | Test Item | Test Value | Unit Conversion | Unit | Standard Value |
|---|---|---|---|---|---|
| $07 | MIN HO2 sensor V | Minimum HO2 sensor voltage | Multiply by 0.005 | V | Lower than 0.45V |
| $08 | MAN HO2 sensor V | Maximum HO2 sensor voltage | Multiply by 0.005 | V | 0.6V or higher |
| $31 | Time $31 | HO2 sensor switch time from Lean to Rich | Multiply by 0.04096 | Second | Less than 3 seconds |
| $32 | Time $32 | HO2 sensor switch time from Rich to Lean | Multiply by 0.04096 | Second | Less than 4 seconds |
| $37 | Time $37 | Time that HO2 sensor voltage drops to 0.2V after fuel-cut began | Multiply by 0.04096 | Second | Less than 7 seconds |
| $39 | Time $39 | Time that HO2 sensor voltage drops from 0.35V to 0.2V after fuel-cut began | Multiply by 0.04096 | Second | Less than 1 seconds |
| $81 | Time $81 | Percentage in monitor time when HO2 sensor voltage is lower than 0.05V | Multiply by 0.3906 | % | Less than 60 % |
| $84 | Time $84 | Percentage in monitor time when HO2 sensor voltage is 0.7V or higher | Multiply by 0.3906 | % | More than 20 % |
| $85 | Time $85 | Maximum time while HO2 sensor voltage exceeded 0.45V continuously | Multiply by 0.2621 | Second | Second More than 20 seconds |
| $87 | Time $87 | Percentage in monitor time when HO2 sensor voltage is 0.45V or higher | Multiply by 0.3906 | % | More than 60 % |
CATALYST MONITOR RESULT
| Test ID | Test Item | Test Result | Unit Conversion | Unit | Test Limit |
|---|---|---|---|---|---|
| $01 | Catalyst (Bank 1) | Ratio of rear HO2 sensor locus length and malfunction threshold | Multiply by 0.0078125 | - | 1 (128) |
A/F SENSOR TEST RESULT
| Test ID | Test Item | Test Value | Unit Conversion | Unit | Test Limit |
|---|---|---|---|---|---|
| $06 | A/F sensor (Bank 1) | Response rate deterioration level for A/F sensor | Multiply by 0.000244 | - | A/F sensor |