Service Data
Cooling Service Data
| Thermostat | ||
| Valve opening temperature | 80 to 84°C (176 to 183°F) | |
| Valve lift | at 95°C (205°F) | 8.5 mm (0.335 in.) or more |
| Radiator cap sub-assy | ||
| Standard opening pressure | 93 to 123 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17.8 psi) | |
| Minimum opening pressure | 78 kPa (0.8 kgf/cm2 , 11.3 psi) | |
| Cooling fan | ||
| Standard amperage | 11.7 to 14.7 A | |
| Cooling fan relay | ||
| Resistance | 3 - 5 | 10 kΩ or higher |
| 3 - 5 (Apply battery voltage to terminals 1 and 2) | Below 1 Ω | |
| Cooling fan relay No. 2 | ||
| Resistance | 3 - 4 | Below 1 Ω |
| 3 - 4 (Apply battery voltage to terminals 1 and 2) | 10 kΩ or higher | |
| 3 - 5 | 10 kΩ or higher | |
| 3 - 5 (Apply battery voltage to terminals 1 and 2) | Below 1 Ω | |
| Cooling fan resistor | ||
| Resistance | at 20°C (68°F) | 1.17 to 1.43 Ω |