O2S TEST DATA FOR REAR O2S (BANK 1 SENSOR 2)

Test ID Description Conversion Factor Unit Note
$07 Minimum O2S voltage Multiply by 0.005 V -
$08 Maximum O2S voltage Multiply by 0.005 V
$31 Switch time from lean to rich Multiply by 0.04 sec. These values are not used for malfunction judgment.
$32 Switch time from rich to lean Multiply by 0.04 sec.
$37 Switch time from rich to lean during fuel-cut Multiply by 0.04 sec.
$39 Switch time from 0.35 V to 0.2 V during fuel-cut Multiply by 0.04 sec.
$81 Percentage of monitoring time when O2S voltage Less than 0.05 V Multiply by 0.3906 % -
$84 Percentage of monitoring time when O2S voltage more than 0.7 V Multiply by 0.3906 %
$85 Maximum rich time Multiply by 0.2621 sec.
$87 Percentage of monitoring time when O2S voltage 0.45 V or more Multiply by 0.3906 %
TEST ID $01: CATALYST - A/F SENSOR TYPE

TLT Component ID Unit Conversion Unit Description
0 $01 Multiply by 0.0078 No dimension Catalyst deterioration level (Bank 1): Determined by waveforms of A/F sensor and O2S
0 $02 Multiply by 0.0078 No dimension Catalyst deterioration level (Bank 1): Determined by waveforms of A/F sensor and O2S
TEST ID $02: EVAP - KEY-OFF TYPE

TLT Component ID Unit Conversion Unit Description
1 $01 Multiply by 0.0156 subtract 2 kPa Test value for small leak (P0456)
1 $02 Multiply by 0.0156 subtract 2 kPa Test value for gross leak (P0455)
1 $03 Multiply by 0.0156 subtract 2 kPa Test value for vacuum pump stuck OFF (P2401)
1 $04 Multiply by 0.0156 subtract 2 kPa Test value for vacuum pump stuck ON (P2402)
1 $05 Multiply by 0.0156 subtract 2 kPa Test value for vent valve stuck OFF (P2420)
1 $06 Multiply by 0.0156 subtract 2 kPa Test value for vent valve stuck ON (P2419)
1 $07 Multiply by 0.0156 subtract 2 kPa Test value for reference orifice low flow (P043E)
1 $08 Multiply by 0.0156 subtract 2 kPa Test value for reference orifice high flow (P043F)
1 $11 Multiply by 0.0156 subtract 2 kPa Test value for purge VSV stuck close (P0441)
1 $12 Multiply by 0.0156 subtract 2 kPa Test value for purge VSV stuck open (P0441)
1 $13 Multiply by 0.0156 subtract 2 kPa Test value for insufficient purge flow (P0441)
TEST ID $04: OXYGEN SENSOR HEATER

TLT Component ID Unit Conversion Unit Description
1 $02 Multiply by 0.000076 Amperage Maximum heater current (Bank 1 Sensor 2)
TEST ID $06: A/F SENSOR

TLT Component ID Unit Conversion Unit Description
0 $01 Multiply by 0.000244 No dimension Parameter to identify A/F sensor response rate (Bank 1)
TEST ID $07: A/F SENSOR HEATER

TLT Component ID Unit Conversion Unit Description
1 $01 Multiply by 0.00017 Amperage Maximum heater current (Bank 1)
TEST ID $08: THERMOSTAT

TLT Component ID Unit Conversion Unit Description
1 $01 Multiply by 0.625 and subtract 40 °C ECT sensor output when estimated ECT reaches malfunction criteria