Service Data: Notes
SERVICE DATA SPECIFICATION
| Refrigerant charge volume | 330 to 390 g (11.6 to 13.8 oz.) |
| Blower resistor | 1 - 4 : 3.12 to 3.60 Ω 3 - 4 : 1.45 to 1.67 Ω 2 - 4 : 0.52 to 0.60 Ω |
| PTC heater assembly | 1 - Ground terminal : Below 1Ω 2 - Ground terminal: Below 1Ω 3 - Ground terminal : Below 1Ω |
| Compressor assembly | 1 - 2 : 10 to 11 Ω |
| Heater blower motor relay | 3 - 4 : Below 1Ω (When battery voltage is absent) 3 - 4 :10 kΩ or higher (When battery voltage applied to terminals 1 and 2) 3 - 5 : 10 kΩ or higher (When battery voltage is absent) 3 - 5 : Below 1Ω (When battery voltage applied to terminals 1 and 2) |
| PTC heater relay | 3 - 5 : 10 kΩ or higher (When battery voltage is absent) 3 - 5 : Below 1Ω (When battery voltage applied to terminals 1 and 2) |