SERVICE DATA SPECIFICATION

Refrigerant charge volume 330 to 390 g (11.6 to 13.8 oz.)
Blower resistor 1 - 4 : 3.12 to 3.60 Ω
3 - 4 : 1.45 to 1.67 Ω
2 - 4 : 0.52 to 0.60 Ω
PTC heater assembly 1 - Ground terminal : Below 1Ω
2 - Ground terminal: Below 1Ω
3 - Ground terminal : Below 1Ω
Compressor assembly 1 - 2 : 10 to 11 Ω
Heater blower motor relay 3 - 4 : Below 1Ω (When battery voltage is absent)
3 - 4 :10 kΩ or higher (When battery voltage applied to terminals 1 and 2)
3 - 5 : 10 kΩ or higher (When battery voltage is absent)
3 - 5 : Below 1Ω (When battery voltage applied to terminals 1 and 2)
PTC heater relay 3 - 5 : 10 kΩ or higher (When battery voltage is absent)
3 - 5 : Below 1Ω (When battery voltage applied to terminals 1 and 2)