Battery Standard voltage 12.5 to 12.9 V at 20°C (68°F)
Charging circuit without load Standard amperage 10 A or less at 2,000 RPM
Standard voltage 13.2 to 14.8 V at 2,000 RPM
Charging circuit with load Standard amperage 30 A or more
Generator brush holder assembly Brush length Standard length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum length 4.5 mm (0.177 in.)
Generator rotor assembly Standard resistance Slip ring 2.3 to 2.7 Ω at 20°C (68°F)
Slip ring - Rotor core 1 MΩ or higher
Slip ring diameter Standard diameter 14.2 to 14.4 mm (0.559 to 0.567 in.)