Sensor Range Charts
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.
NOTE:
All voltage tests should be performed with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure.
AIRFLOW METER VOLTAGE TEST
| Application |
Wire Colors |
Volts |
| Legacy |
|
0-0.3 |
| Loyale |
| 1.8L PFI |
|
1.0-2.0 |
| 1.8L TBI |
White & Black |
0.1-0.5 |
| XT & XT6 |
White & Black/Red |
1.0-2.0 |
AIR TEMPERATURE SENSOR RESISTANCE (JUSTY - CARBURETED)
| Temperature |
Ohms |
| 68°F (20°C) |
2000-3000 |
| 176°F (80°C) |
270-370 |
Atmospheric Pressure Sensor
For testing information, see SELF-DIAGNOSTICS article.
COOLANT TEMPERATURE SENSOR RESISTANCE
| Application |
Temperature |
Ohms |
| Justy 1.2L PFI & Legacy |
68°F (20°C) |
2000-3000 |
| " |
176°F (80°C) |
270-330 |
| All Others |
14°F (-10°C) |
7000-11,500 |
| All Others |
68°F (20°C) |
2000-3000 |
| All Others |
122°F (50°C) |
700-1000 |