Starter Interlock Relay Test
- Interlock relay has a Blue, 4-terminal connector and is located below and to far left of EFC/PFI control unit. EFC/PFI control unit is located behind left side of instrument panel. Disconnect interlock relay connector.
- Connect test light to Black/White wire terminal of interlock relay. Using jumper wire, apply 12 volts to both Black/Yellow wire terminals of interlock relay.
- Using another jumper wire connected to ground, momentarily touch jumper wire to Black/Blue wire terminal of interlock relay. Test light should come on. If test light does no come on, replace interlock relay.