lemon-mirror:
Home >> Subaru >> 1994 >> Loyale Automatic >> Repair and Diagnosis >> Electrical >> Starter >> Starter Specifications

Starter Specifications

STARTER SPECIFICATIONS

Application Specification
Carbon Brushes
Minimum Length .35" (9.0 mm)
Standard Length .55" (14.0 mm)
Commutator Runout
Limit .0020" (.050 mm)
Standard .0008" (.020 mm)
Commutator Outside Diameter
Limit 1.14" (29.0 mm)
Standard 1.18" (30.0 mm)
Commutator Mica Depth
Limit .008" (.20 mm)
Standard .020-.031" (.50-.80 mm)
Load Test (A/T)
Load 10 Ft. Lbs. (14 N.m)
Maximum Amps 370 Amps
Minimum RPM 880 RPM
Voltage Drop (Minimum) 8 Volts
Load Test (M/T)
Load 4.7 Ft. Lbs. (6.4 N.m)
Maximum Amps 230 Amps
Minimum RPM 1180 RPM
Voltage Drop (Minimum) 8 Volts
Lock Test (A/T)
Minimum Voltage 5 Volts
Maximum Amps 735 Amps
Minimum Torque 20 Ft. Lbs. (27 N.m)
Lock Test (M/T)
Minimum Voltage 2.5 Volts
Maximum Amps 300 Amps
Minimum Torque 5.1 Ft. Lbs. (7.0 N.m)
No-Load Test
Maximum Amps 90 Amps
Minimum RPM (A/T) 4000 RPM
Minimum RPM (M/T) 3000 RPM
Voltage Drop (Minimum) 11 Volts