STARTER SPECIFICATIONS

Application Specification
Carbon Brushes
Minimum Length .45" (11.5 mm)
Standard Length .67" (17.0 mm)
Commutator Runout
Limit .0039" (.100 mm)
Standard .0020" (.050 mm)
Commutator Outside Diameter (1)
Commutator Mica Depth
Limit .008" (.20 mm)
Standard .020-.031" (.50-.80 mm)
Load Test
Load 7 Ft. Lbs. (10 N.m)
Maximum Amps 300 Amps
Minimum RPM 1000 RPM
Voltage Drop (Minimum) 7.7 Volts
Lock Test
Minimum Voltage 4 Volts
Maximum Amps 980 Amps
Minimum Torque 17 Ft. Lbs. (23 N.m)
No-Load Test
Maximum Amps 90 Amps
Minimum RPM 3000 RPM
Voltage Drop (Minimum) 11 Volts