Generator & Regulator: Overhaul
NOTE:
Refer to illustration for exploded view of generator. See Fig 1
To remove a stuck rear cover after removing case bolts, use soldering iron/gun to heat rear cover bearing housing to about 122-140°F (50-60°C). This action will expand housing enough to slide cover off rear rotor bearing. Ensure that spring washer located in rear cover bearing bore is not lost during disassembly.