lemon-mirror:
Home >> Subaru >> 1997 >> Legacy Outback, Automatic >> Repair and Diagnosis >> Electrical >> Starter >> Starter Specifications

Starter Specifications

STARTER SPECIFICATIONS

Application Specification
Carbon Brushes
Minimum Length .35" (9.0 mm)
Standard Length .55" (14.0 mm)
Commutator Runout
Limit .0020" (.050 mm)
Standard .0008" (.020 mm)
Outside Diameter
Limit 1.14" (29.0 mm)
Standard 1.18" (30.0 mm)
Mica Depth
Limit .008" (.20 mm)
Standard .020-.031" (.50-.80 mm)
Load Test (A/T)
Load 10 Ft. Lbs. (14 N.m)
Maximum Amps 370 Amps
Minimum RPM 880 RPM
Voltage Drop (Minimum) 8 Volts
Load Test (M/T)
Load 7 Ft. Lbs. (10 N.m)
Maximum Amps 280 Amps
Minimum RPM 900 RPM
Voltage Drop (Minimum) 8 Volts
Lock Test
Maximum Amps (A/T) 1050 Amps
Maximum Amps (M/T) 800 Amps
Minimum Torque 20 Ft. Lbs. (27 N.m)
No-Load Test
Maximum Amps 90 Amps
Minimum RPM (A/T) 3350 RPM
Minimum RPM (M/T) 3000 RPM
Voltage Drop (Minimum) 11 Volts