Inhibitor Switch: Adjustment
- Shift the select lever to "N" range.
- Loosen the three inhibitor switch securing bolts.
- Insert the ST as vertical as possible into the holes in inhibitor switch lever and switch body.
- Tighten the three inhibitor switch bolts.
- Tightening torque: 3.5 N.m (0.35 kgf.m, 2.5 ft.lb)
- Repeat the above checks. If the inhibitor switch is determined to be "faulty", replace it.