Inhibitor Switch: Adjustment
- Shift the select lever to "N" range.
- Loosen the three inhibitor switch assembly securing bolts.
- Insert the ST as vertical as possible into the holes in inhibitor switch lever and switch body.
- ST 499267300 STOPPER PIN
- Tighten the three inhibitor switch assembly bolts.
- Tightening torque: 3.4 N.m (0.35 kgf-m, 2.6 ft-lb)
- Repeat the above checks. If the inhibitor switch is determined to be "faulty", replace it. < Ref. to INSPECTION . >