Check Security Indicator Light Circuit
STEP CHECK SHEET
| Step | Check | Yes | No |
|---|---|---|---|
1. CHECK SECURITY INDICATOR LIGHT.
Connector & terminal (184) No. 33 - Chassis ground: |
Does the security indicator light illuminate? | Check the body integrated unit. < Ref. to , BASIC DIAGNOSTIC PROCEDURE . > | Go to step 2. |
2. CHECK POWER SUPPLY FOR SECURITY INDICATOR LIGHT.
Connector & terminal (i10) No. 1, 2 (+) - Chassis ground (-): |
Is the voltage more than 10 V? | Go to step 3. | Check the harness for open or short circuit between combination meter and fuse. |
| 3. CHECK SECURITY INDICATOR LIGHT CIRCUIT. Measure the resistance between the combination meter harness connector terminal and security control unit harness connector terminal. Connector & terminal (i10) No. 17 - (i84) No. 33: |
Is the resistance less than 10 Ω? | Replace the combination meter. < Ref. to COMBINATION METER . > | Check the harness for open or short circuit between combination meter and body integrated unit. |