STARTING/CHARGING SYSTEMS (H4SO) SPECIFICATION

Item Specification
Vehicle model MT AT
Starter Type Reduction type
Model 428000-2300 428000-2290
Manufacturer DENSO
Voltage and output 12 V - 1.0 kW 12 V - 1.4 kW
Revolving direction Counterclockwise (when observed from pinion)
Number of pinion teeth 9 9
No-load characteristics Voltage 11 V 11 V
Current 90 A or less 90 A or less
Rotating speed 1,820 RPM or more 1,720 RPM or more
Load characteristics Voltage 8V 8V
Current 280 A 370 A
Torque 7.76 N.m (0.79 kgf-m, 5.7 ft-lb) or more 12.78 N.m (1.30 kgf-m, 9.4 ft-lb) or more
Rotating speed 900 RPM or more 850 RPM or more
Lock characteristics Voltage 3V 3V
Current 900 A or less 900 A or less
Torque 13.62 N.m (1.39 kgf-m, 10.0 ft-lb) or more 15.42 N.m (1.57 kgf-m, 11.3 ft-lb) or more
Generator Model Rotating-field three-phase type, voltage regulator built-in type, with load response control system
Model 2.5 L Non-Turbo A003TG2391ZC
3.0 L Non-Turbo A003TB1891
2.5 L Turbo A003TG0491
Manufacturer Mitsubishi Electric
Voltage and output 2.5 L Non-Turbo and 2.5 L Turbo 12V - 110 A
3.0 L Non-Turbo 12V - 100A
Polarity on ground side Negative
Revolving direction Clockwise (when observed from pulley side)
Armature connection 3-phase Y-type
Output current 2.5 L Non-Turbo and 2.5 L Turbo 1,500 RPM - 50 A or more
2,500 RPM - 91 A or more
5,000 RPM - 105 A or more
3.0 L Non-Turbo 1,500 RPM - 43 A or more
2,500 RPM - 76 A or more
5,000 RPM - 100 A or more
Regulated voltage 14.1 - 14.8 V [20° (68°)]
Battery Type and capacity 12 V - 48 AH (55D23L) 12 V - 52 AH (75D23L)