Keyless Entry Control Module
TERMINAL REFERENCE CHART
| Content | Terminal No. | Measuring condition |
|---|---|---|
| Turn signal light (Left) | 1 (OUTPUT) | Battery voltage is present when pressing the transmitter UNLOCK/DISARM or LOCK/ARM button. |
| Power supply (Back-up) | 2 | Battery voltage is constantly present. |
| Keyless buzzer | 3 (OUTPUT) | 0 V is present when pressing the transmitter UNLOCK/DISARM or LOCK/ARM button. |
| Door lock switch | 4 (INPUT) | 0 V is present when unlocking the door lock switch. |
| Door lock switch | 5 (INPUT) | 0 V is present when locking the door lock switch. |
| Door switch | 6 (INPUT) | 0 V is present when any door is opened. |
| Key warning switch | 9 (INPUT) | Battery voltage is present when inserting the key into the ignition switch. |
| Ignition switch (ON) | 10 (INPUT) | Battery voltage is present when ignition switch is turned to ON. |
| Turn signal light (Right) | 13 (OUTPUT) | Battery voltage is present when pressing the transmitter UNLOCK/DISARM or LOCK/ARM button. |
| Ground | 14 | 0 V is constantly present. |
| Integrated module | 18 (OUTPUT) | 0 V is present when pressing the transmitter UNLOCK/DISARM button. |
| Integrated module | 19 (OUTPUT) | 0 V is present when pressing the transmitter LOCK/ARM button. |
| Horn relay | 24 (OUTPUT) | 0 V is present when pressing the transmitter LOCK/ARM for approximately 2 seconds and the panic alarm is activated. |
| Power supply (Back-up) | 26 | Battery voltage is constantly present. |