Data Link Connector: Note
- This connector is used both for general scan tools and the Subaru Select Monitor.
- Terminal No. 4 to No. 6 of the data link connector is used for the Subaru Select Monitor signal.
CAUTION:
Do not connect any scan tools other than the general scan tools and the Subaru Select Monitor, because the circuit for the Subaru Select Monitor may be damaged.
ELECTRICAL SPECIFICATION
| Terminal No. | Contents | Terminal No. | Contents |
|---|---|---|---|
| 1 | Power supply | 9 | Blank |
| 2 | Blank | 10 | K line of ISO 9141 CARB |
| 3 | Blank | 11 | Blank |
| 4 | Blank | 12 | Ground |
| 5 | Blank | 13 | Ground |
| 6 | Flash Write | 14 | Blank |
| 7 | Blank | 15 | Blank |
| 8 | Blank | 16 | Blank |