Check Room Light Operation
ROOM LIGHT OPERATION CHECKING PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK ROOM LIGHT OPERATION. Make sure the room light illuminates when the room light switch is turned to ON. |
Does the room light illuminate? | Go to step 2. | Check the room light circuit. |
2 CHECK HARNESS BETWEEN ROOM LIGHT AND BODY INTEGRATED UNIT.
|
Is the resistance less than 10 Ω? | The room light operation circuit is OK. | Check the harness for open or short between body integrated unit and room light. |