lemon-mirror:
Home >> Subaru >> 2006 >> Outback R >> Repair and Diagnosis >> Electrical >> Charging Systems >> Starting/Charging Systems (H4SO) >> Generator >> Removal

Starting/Charging Systems (H4SO): Generator: Removal

  1. Disconnect the ground cable from battery.
    Fig 1: Disconnecting Ground Cable From Battery
    G05019586
  2. Disconnect the connector and terminal from generator.
    • 2.5 L Non-turbo model
      Fig 2: Identifying Generator Connector - 2.5 L Non-Turbo Model
      G04997958
    • 3.0 L Non-turbo model
      Fig 3: Identifying Generator Connector - 3.0 L Non-Turbo Model
      G05017447
    • Turbo model
      Fig 4: Identifying Generator Connector - Turbo Model
      G05017448
  3. Remove the V-belt covers.
  4. Remove the V-belts.

    < Ref. to FRONT SIDE BELT (H4SO) , REMOVAL, V-belt. > or < Ref. to FRONT SIDE BELT (H4DOTC) , REMOVAL, V-belt. > < Ref. to REMOVAL , V-belt. >

  5. Remove the bolts which install the generator onto bracket.
    Fig 5: Locating Generator Bolts
    G05017449