lemon-mirror:
Home >> Subaru >> 2007 >> Forester X, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls (Diagnostics) (H4SO) >> Compulsory Valve Operation Check Mode >> Operation

Compulsory Valve Operation Check Mode: Operation

  1. Prepare the Subaru Select Monitor kit. <Ref. to PREPARATION TOOL , General Description. >
  2. Connect the diagnosis cable to the Subaru Select Monitor.
  3. Connect the test mode connector (A) at the lower portion of instrument panel (on the driver's side).
    Fig 1: Identifying Test Mode Connector
    G04993022Courtesy of SUBARU OF AMERICA, INC.
  4. Connect the Subaru Select Monitor to the data link connector.
    1. Data link connector is located in the lower portion of instrument panel (on the driver's side).
      Fig 2: Identifying Data Link Connector Location
      G04997584Courtesy of SUBARU OF AMERICA, INC.
    2. Connect the diagnosis cable to the data link connector.
      CAUTION: Do not connect scan tools except for Subaru Select Monitor and general scan tool.
  5. Turn the ignition switch to ON (engine OFF) and run the Subaru Select Monitor.
  6. On the «Main Menu» display screen, select the {Each System Check}.
  7. On the «System Selection Menu» display screen, select the {Engine Control System}.
  8. Select the [OK] after the information of engine type has been displayed.
  9. On the «Engine Diagnosis» display screen, select the {System Operation Check Mode}.
  10. On the «System Operation Check Mode» display screen, select the {Actuator ON/OFF Operation}.
  11. Select the desired compulsory actuator on the «Actuator ON/OFF Operation» display screen.
  12. Selecting the [NO] completes the compulsory valve operation check mode. The display will then return to the "Actuator ON/OFF Operation" screen.