Service Limit
Make a measurements as follows. If it exceeds the service limit, replace with a new part.
CAUTION:
- When securing the oil pump on a vise, hold the oil pump with the least possible force between two pieces of wood.
- Do not set the outside of flow control valve or pulley on a vise; otherwise outside or pulley might be deformed. Select properly sized wood pieces.
- Play of the pulley shaft
Condition:
P: When applying the force of 9.8 N (1.0 kgf, 2.2 lb)
Service limit:
Play in the radial direction (Direction ← → )
0.4 mm (0.016 in) or less
Axial play (Direction ← → )
0.9 mm (0.035 in) or less
- Deflection of the pulley groove
Service limit:
1.0 mm (0.039 in) or less
NOTE: Read the value for one surface of V ditch, and then the value for another off the dial gauge. - Rotating resistance of pulley
Service limit:
Maximum load: 9.22 N (0.94 kgf, 2.07 lb) or less