lemon-mirror:
Home >> Subaru >> 2008 >> Tribeca Base >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Fuel Injection System (H6DO) >> Oil Flow Control Solenoid Valve >> Removal >> Intake Side

Intake Side

  1. Remove the collector cover.
  2. Disconnect the ground cable from battery.
  3. Remove the generator harness from the fuel protector RH.
  4. Disconnect the connector from intake oil flow control solenoid valve RH.
    Fig 1: Identifying Intake Oil Flow Control Solenoid Valve Connector RH
    G05667602Courtesy of SUBARU OF AMERICA, INC.
  5. Remove the intake oil flow control solenoid valve RH.
    Fig 2: Identifying Intake Oil Flow Control Solenoid Valve Connector RH
    G05667603Courtesy of SUBARU OF AMERICA, INC.
  6. Remove the intake oil flow control solenoid valve LH in the same procedure as RH.