Remote Control Mirror Switch: Inspection
- Check the resistance between switch door mirror terminals.
Preparation tool:
Circuit tester
- Changeover switch, right side (model without electric retractable mirror)
Terminal No. Inspection conditions Standard 12 - 1
12 - 18OFF 1 MΩ or more 12 - 18
17 - 1UP Less than 1 Ω 12 - 17
18 - 1DOWN Less than 1 Ω 12 - 16
18 - 1LEFT Less than 1 Ω 12 - 18
16 - 1RIGHT Less than 1 Ω - Changeover switch, left side (model without electric retractable mirror)
Terminal No. Inspection conditions Standard 12 - 1
12 - 21OFF 1 MΩ or more 12 - 20
21 - 1DOWN Less than 1 Ω 12 - 21
20 - 1UP Less than 1 Ω 12 - 19
21 - 1LEFT Less than 1 Ω 12 - 21
19 - 1RIGHT Less than 1 Ω - Changeover switch, left side (model with electric retractable mirror)
Terminal No. Inspection conditions Standard 12 - 1
12 - 21OFF 1 MO or more 12 - 20
21 - 1DOWN Less than 1 O 12 - 21
20 - 1UP Less than 1 O 12 - 19
21 - 1LEFT Less than 1 O 12 - 21
19 - 1RIGHT Less than 1 O - Folding switch (model with electric retractable mirror)
Terminal No. Inspection conditions Standard 12 - 5
4 - 1Retraction Less than 1 O 12 - 4
5 - 1Unfolding Less than 1 O
- Changeover switch, right side (model without electric retractable mirror)
- If the inspection result is not within the standard value, replace the switch assembly power window main.