lemon-mirror:
Home >> Subaru >> 2021 >> Forester Base >> Repair and Diagnosis >> Accessories & Equipment >> Collision/Avoidance >> Eyesight System >> Camera Adjustment, Inspection >> Procedure >> Camera Initialization

Camera Initialization

This is a recovery measures prepared for the data failure caused by the low battery voltage during data storage to inside the stereo camera.

CAUTION: Do not usually perform camera initialization because it will clear the camera adjustment and inspection data and/or DTCs.

Perform the camera initialization only when the camera adjustment and inspection result is NG even if the vehicle is placed correctly as shown in the flowchart described in "A: Procedure". After camera initialization, perform camera adjustment and inspection in the same procedure as for camera replacement.

  1. Using the Subaru Select Monitor, select [Clear memory] from the diagnostic code item list of [EyeSight] while pressing the pre-collision brake OFF switch and the lane departure warning OFF switch at the same time. Ref. to EYESIGHT (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .
  2. Turn the ignition switch to OFF and wait for 5 seconds.
  3. Next, perform the adjustment value clear operation. Ref. to EYESIGHT>Camera Adjustment, Inspection>PROCEDURE>ADJUSTMENT VALUE CLEAR .