Variant Work
Perform when replacing the combination meter assembly.
- When communication with Subaru Select Monitor is possible ([Read and store the ECM setting information] is workable): Perform the operation procedure A.
- When communication with Subaru Select Monitor is possible ([Read and store the ECM setting information] is not workable): Perform the operation procedure B.CAUTION:
- Subaru Select Monitor is required for variant work.
- If an error is displayed during the work, click the [OK] button and perform the variant work again.
- When odometer value reading is performed, the odometer displays "________" and continued use of the combination meter assembly is impossible.
- When the odometer writing operation is completed correctly, the odometer value is automatically cleared from the Subaru Select Monitor.
OPERATION PROCEDURE A
- Read and store the ECM setting information.
- Connect the Subaru Select Monitor.
- Select [Read Control module setting information] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
- According to the display screen, save and close the file.
- Read the odometer value.NOTE: Perform the same operation procedures as those of reading and storing the ECM setting information.
- Select [Reading and Writing of the ECU Configuration Information and Odometer Value] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
- Perform the operation according to the display screen.
- Replace the combination meter assembly with a new part.
- Write the odometer value.
- Perform the operation according to the display screen.
- Write the ECM setting information.NOTE: Perform the same operation procedures as those of reading and storing the ECM setting information.
- Select [Write Control module setting information] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
- On the item list, select [Write ECU setting save data].
- Perform the operation according to the display screen.
- When [Write operation was completed.] is displayed, select the [OK] button.
- Check if the combination meter assembly operates normally.
OPERATION PROCEDURE B
- Replace the combination meter assembly with a new part.
- Write the vehicle data.
- Connect the Subaru Select Monitor.
- Select [Write Control module setting information] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
- From the item list, select [Write ECU setting 12 columns of models]. Enter the applied model and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER AND LABEL LOCATIONS .
- Enter the option code and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER AND LABEL LOCATIONS .
- Confirm the vehicle information on [Write ECU setting 12 columns of models] screen, and click the [OK] button.
- When [Write?] is displayed, select the [Yes] button.
- Confirm that [Write operation is complete.] is displayed, and click the [OK] button.
- Check if the combination meter assembly operates normally.