lemon-mirror:
Home >> Subaru >> 2021 >> Forester Base >> Repair and Diagnosis >> Electrical >> Gauges >> Instrumentation System & Driver Information Center >> Combination Meter System >> Operation >> Variant Work

Variant Work

Perform when replacing the combination meter assembly.

OPERATION PROCEDURE A 

  1. Read and store the ECM setting information.
    1. Connect the Subaru Select Monitor.
    2. Select [Read Control module setting information] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
    3. According to the display screen, save and close the file.
  2. Read the odometer value.
    NOTE: Perform the same operation procedures as those of reading and storing the ECM setting information.
    1. Select [Reading and Writing of the ECU Configuration Information and Odometer Value] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
    2. Perform the operation according to the display screen.
  3. Replace the combination meter assembly with a new part.
  4. Write the odometer value.
    1. Perform the operation according to the display screen.
  5. Write the ECM setting information.
    NOTE: Perform the same operation procedures as those of reading and storing the ECM setting information.
    1. Select [Write Control module setting information] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
    2. On the item list, select [Write ECU setting save data].
    3. Perform the operation according to the display screen.
    4. When [Write operation was completed.] is displayed, select the [OK] button.
  6. Check if the combination meter assembly operates normally.

OPERATION PROCEDURE B 

  1. Replace the combination meter assembly with a new part.
  2. Write the vehicle data.
    1. Connect the Subaru Select Monitor.
    2. Select [Write Control module setting information] on [Work Support] of Subaru Select Monitor. Ref. to COMMON (DIAG)>WORK SUPPORT .
    3. From the item list, select [Write ECU setting 12 columns of models]. Enter the applied model and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER AND LABEL LOCATIONS .
    4. Enter the option code and click the [OK] button. Ref. to IDENTIFICATION>IDENTIFICATION NUMBER AND LABEL LOCATIONS .
    5. Confirm the vehicle information on [Write ECU setting 12 columns of models] screen, and click the [OK] button.
    6. When [Write?] is displayed, select the [Yes] button.
    7. Confirm that [Write operation is complete.] is displayed, and click the [OK] button.
  3. Check if the combination meter assembly operates normally.