Bench Testing: Rectifier
Connect ohmmeter leads between "B" and "E" terminals on rectifier and note continuity reading. See Fig 1 . Reverse ohmmeter leads on rectifier and note continuity reading. Continuity should exist with ohmmeter leads in one direction, and no continuity should exist when ohmmeter leads are reversed. Replace rectifier if defective.