Power Mirror Switch
Remove power mirror switch from instrument panel. Ensure continuity exists between appropriate power mirror switch terminals with switch in specified position. See POWER MIRROR SWITCH CONTINUITY table. See Fig 1 . If continuity is not as specified, replace power mirror switch. If continuity is as specified, see POWER MIRROR MOTOR .
POWER MIRROR SWITCH CONTINUITY
| Switch Position | Terminals No. | |
|---|---|---|
| Left Side | ||
| Up | 4 & 5; 6 & 7 | |
| Down | 4 & 7; 5 & 6 | |
| Left | 5 & 8; 6 & 7 | |
| Right | 5 & 6; 7 & 8 | |
| Right Side | ||
| Up | 3 & 5; 6 & 7 | |
| Down | 3 & 7; 5 & 6 | |
| Left | 5 & 9; 6 & 7 | |
| Right | 5 & 6; 7 & 9 | |