lemon-mirror:
Home >> Suzuki >> 2003 >> XL-7 Base, RWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generators & Regulators >> Bench Testing >> Condenser >> 70A

Bench Testing: Condenser: 70A

Using capacitor tester, check capacity of condenser, located on rectifier. See Fig 1. Replace rectifier if condenser capacity is not .5 uF.

Fig 1: Testing Condenser Capacity (70A)
G96B11289Courtesy of SUZUKI OF AMERICA CORP.