Installation Procedure
- Install the brake modulator assembly.
- Install the mounting bracket bolts on the hydraulic unit.
Tighten: Tighten the torque ABS mounting bracket bolts to 22 N.m (16 lb ft).
- Install the brake pipes fitting nuts from the hydraulic unit.
Tighten: Tighten the torque brake pipe fitting nuts to 16 N.m (12 lb ft).
- Connect the ABS wiring harness connector to its socket on the EBCM.
- Connect the negative battery cable.
- Add new brake fluid and bleed the brake system. Refer to Hydraulic Brake System Bleeding (Manual) or Hydraulic Brake System Bleeding (Pressure) in Hydraulic Brakes.
- Inspect the brake system for leaks.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.
NOTE:
Refer to Brake Fluid Effects on Paint and Electrical Components Notice
in Cautions and Notices.