lemon-mirror:
Home >> Suzuki >> 2007 >> SX4 Base, Automatic >> Repair and Diagnosis >> Electrical >> Starter System >> Specifications >> Cranking System Specifications

Cranking System Specifications

CRANKING SYSTEM SPECIFICATIONS

Voltage 12 volts
Output 1.4 kW
Rating 30 seconds
Direction of rotation Clockwise as viewed from pinion side
Brush length Standard: 12.3 mm (0.48 in.) Limit: 7.0 mm (0.28 in.)
Number of pinion teeth 8
Performance Condition Guarantee
Around at 20 °C (68 °F) No load characteristic 11.0 V 90 A maximum
2,000 RPM minimum
Load characteristic 7.5 V 300 A 11 N.m (1.1 kgf-m, 8.0 lb-ft) minimum
840 RPM minimum
Locked characteristic 3.0 V 860 A maximum
20 N.m (2.0 kgf-m, 14.5 lb-ft) minimum
Magnetic switch operating voltage 8 volts maximum