lemon-mirror:
Home >> Suzuki >> 2007 >> XL7 Base, FWD >> Repair and Diagnosis >> Engine Performance >> Fuel Delivery >> Fuel System >> Repair Instructions >> Secondary Fuel Tank Module Replacement >> Installation Procedure

Installation Procedure

  1. If the fuel level sending unit is being replaced, install the fuel level sending unit into the new fuel pump. Refer to INSTALLATION PROCEDURE .
    Fig 1: Identifying Secondary Level Sensor Electrical Connector Tab
    G04843434Courtesy of SUZUKI OF AMERICA CORP.
  2. Connect the suction port (1).
    Fig 2: Identifying Secondary Fuel Pump Module
    G04843435Courtesy of SUZUKI OF AMERICA CORP.
  3. Insert the new secondary fuel pump module (2) with the level sender and new fuel pump-to-tank seal. Ensure the orientation tabs are aligned.
  4. Use the J39765-A to install the fuel pump lock ring.
  5. Connect the EVAP line quick connect. Refer to PLASTIC COLLAR QUICK CONNECT FITTING SERVICE .
  6. Install the fuel tank. Refer to INSTALLATION PROCEDURE  and INSTALLATION PROCEDURE .