Pull-In Coil Test
Connect jumper wire from negative battery terminal to terminal "C" and starter housing. Connect positive battery terminal to terminal No. 50. See Fig 1. Plunger should extend. If not, replace solenoid.
Connect jumper wire from negative battery terminal to terminal "C" and starter housing. Connect positive battery terminal to terminal No. 50. See Fig 1. Plunger should extend. If not, replace solenoid.