Sensor Operating Specifications
NOTE:
Perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure.
AIRFLOW METER RESISTANCE SPECIFICATIONS
| Application & Terminals |
Ohms |
| E2-Vs |
| Measuring Plate Fully Closed |
200-600 |
| Measuring Plate Fully Open |
20-1200 |
| E2-THA |
| -4°F (-20°C) |
10,000-20,000 |
| 32°F (0°C) |
4000-7000 |
| 68°F (20°C) |
2000-3000 |
| 104°F (40°C) |
900-1300 |
| 140°F (60°C) |
400-700 |
NOTE:
On MR2 Non-Turbo, air temperature sensor is mounted on intake air box. On Turbo models, air temperature sensor is an integral part of airflow meter. For air temperature sensor specifications, see Fig 1.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002 COLD START INJECTOR RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| All Engines |
2.0-4.0 |
COLD START INJECTOR TIME SWITCH RESISTANCE SPECIFICATIONS
| Terminals |
Temperature: °F (°C) |
Ohms |
| Non-Turbo |
| STA-STJ |
Less Than 86 (30) |
20-40 |
| " |
Greater Than 104 (40) |
40-60 |
| STA-Ground |
N/A |
20-80 |
| Turbo |
| STA-STJ |
Less Than 50 (10) |
30-50 |
| " |
Greater Than 77 (25) |
70-90 |
| STA-Ground |
N/A |
30-90 |
NOTE:
For coolant temperature sensor specifications, see Fig 2.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002 EGR GAS TEMP SENSOR SPECIFICATIONS
| Temperature: °F (°C) |
Ohms |
| 122 (50) |
69-89 |
| 212 (100) |
12-14 |
| 302 (150) |
3-4 |
FUEL INJECTOR RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| Turbo |
2.0-4.0 |
| Non-Turbo |
13.8 |
ISC VALVE RESISTANCE SPECIFICATIONS
| Application |
Ohms |
| Turbo |
18-24 |
| Non-Turbo |
19-22 |
OXYGEN SENSOR HEATER RESISTANCE SPECIFICATIONS
| Application |
Condition |
Ohms |
| All Engines |
68°F (20°C) |
5.1-6.3 |
TPS RESISTANCE SPECIFICATIONS
| Model/ Application |
Clearance In. (mm) |
Terminal Identification |
Ohmmeter Reading |
| 2.2L (A/T) & 2.0L Turbo |
IDL & E2 . .020 (.51) |
2300 Or Less |
" |
| " |
.028 (.71) |
No Continuity |
" |
| VTA & E2 |
0 (0) |
200-800 |
" |
| " |
Fully Open |
3300-10,300 |
" |
| VC & E2 |
N/A |
3000-8300 |
2.2L (M/T) |
| IDL & E1 |
.020 (.50) |
Continuity |
" |
| " |
.035 (.90) |
No Continuity |
" |
| " |
Fully Open |
No Continuity |
" |
| PSW & E1 |
.020 (.50) |
No Continuity |
" |
| " |
.035 (.90) |
No Continuity |
" |
| " |
Fully Open |
Continuity |
" |
TURBO PRESSURE SENSOR SPECIFICATIONS
| Applied Vacuum: In. Hg |
Voltage Drop |
| 3.94 |
.15-.35 |
| 7.87 |
.40-.60 |
| 11.81 |
.65-.85 |
| 15.75 |
.90-1.10 |
| 19.69 |
1.15-1.35 |
VACUUM SENSOR SPECIFICATIONS
| Vacuum: In. Hg |
Voltage Drop |
| 3.94 |
.3-.5 |
| 7.87 |
.7-.9 |
| 11.81 |
1.1-1.3 |
| 15.75 |
1.5-1.7 |
| 19.69 |
1.9-2.1 |