lemon-mirror:
Home >> Toyota >> 1991 >> MR2 2.0 S >> Repair and Diagnosis >> Engine Performance >> Sensor Range Charts >> Engine Controls - Sensor Operating Range Charts >> Sensor Operating Specifications

Sensor Operating Specifications

NOTE: Perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure.
AIRFLOW METER RESISTANCE SPECIFICATIONS

Application & Terminals Ohms
E2-Vs
Measuring Plate Fully Closed 200-600
Measuring Plate Fully Open 20-1200
E2-THA
-4°F (-20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
NOTE: On MR2 Non-Turbo, air temperature sensor is mounted on intake air box. On Turbo models, air temperature sensor is an integral part of airflow meter. For air temperature sensor specifications, see Fig 1.
Fig 1: Air Temperature Sensor Specifications Chart (Non-Turbo)
G119427Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
COLD START INJECTOR RESISTANCE SPECIFICATIONS

Application (1) Ohms
All Engines 2.0-4.0
(1) Measure resistance between injector terminals.
COLD START INJECTOR TIME SWITCH RESISTANCE SPECIFICATIONS

Terminals Temperature: °F (°C) Ohms
Non-Turbo
STA-STJ Less Than 86 (30) 20-40
" Greater Than 104 (40) 40-60
STA-Ground N/A 20-80
Turbo
STA-STJ Less Than 50 (10) 30-50
" Greater Than 77 (25) 70-90
STA-Ground N/A 30-90
NOTE: For coolant temperature sensor specifications, see Fig 2.
Fig 2: Coolant Temperature Sensor Specifications
G119427Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
EGR GAS TEMP SENSOR SPECIFICATIONS

Temperature: °F (°C) (1) Ohms
122 (50) 69-89
212 (100) 12-14
302 (150) 3-4
(1) Measure resistance between sensor terminals.
FUEL INJECTOR RESISTANCE SPECIFICATIONS

Application (1) Ohms
Turbo 2.0-4.0
Non-Turbo 13.8
(1) Measured across terminals at 68°F (20°C).
ISC VALVE RESISTANCE SPECIFICATIONS

Application Ohms
Turbo (1) 18-24
Non-Turbo (2) 19-22
(1) Measure resistance between terminals +B to RSC or RSO.
(2) Measure resistance between terminals +B to ISCC or ISCO.
OXYGEN SENSOR HEATER RESISTANCE SPECIFICATIONS

Application Condition Ohms
All Engines (1) 68°F (20°C) 5.1-6.3
(1) Measure resistance between terminals B+ and HT.
TPS RESISTANCE SPECIFICATIONS

Model/ Application Clearance In. (mm) Terminal Identification Ohmmeter Reading
2.2L (A/T) & 2.0L Turbo IDL & E2 . .020 (.51) 2300 Or Less "
" .028 (.71) No Continuity "
VTA & E2 0 (0) 200-800 "
" Fully Open 3300-10,300 "
VC & E2 N/A 3000-8300 2.2L (M/T)
IDL & E1 .020 (.50) Continuity "
" .035 (.90) No Continuity "
" Fully Open No Continuity "
PSW & E1 .020 (.50) No Continuity "
" .035 (.90) No Continuity "
" Fully Open Continuity "
TURBO PRESSURE SENSOR SPECIFICATIONS

Applied Vacuum: In. Hg (1) Voltage Drop
3.94 .15-.35
7.87 .40-.60
11.81 .65-.85
15.75 .90-1.10
19.69 1.15-1.35
(1) Voltage drop is from measured voltage of pressure sensor (harness connector terminals VC and E2). Measure voltage between ECU connector terminals PIM and E2. See I - SYS/COMP TESTS article in this section.
VACUUM SENSOR SPECIFICATIONS (1)

Vacuum: In. Hg (2) Voltage Drop
3.94 .3-.5
7.87 .7-.9
11.81 1.1-1.3
15.75 1.5-1.7
19.69 1.9-2.1
(1) Vacuum sensor is also known as MAP sensor.
(2) Voltage drop is from measured voltage of pressure sensor (harness connector terminals VCC and E2). Measure voltage between ECU connector terminals PIM and E2. See I - SYS/COMP TESTS article in this section.