Sensor Operating Specifications

NOTE: Perform all voltage tests with a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance, unless stated otherwise in test procedure.
AIRFLOW METER RESISTANCE SPECIFICATIONS

Application & Terminals Ohms
Non Turbo
E2-Vc 200-400
E1-Fc
Measuring Plate Fully Closed No Continuity
Measuring Plate Other Than Closed 0
E2-Vs
Measuring Plate Fully Closed 200-600
Measuring Plate Fully Opened 20-1000
Turbo
Ks-E1 No Continuity
E1-Ks 5000-10,000
Vc-E1 10,000-15,000
E1-Vc 5000-10,000
All Models
E2-THA
-4°F (-20°C) 10,000-20,000
32°F (0°C) 4000-7000
68°F (20°C) 2000-3000
104°F (40°C) 900-1300
140°F (60°C) 400-700
COLD START INJECTOR RESISTANCE SPECIFICATIONS

Application (1) Ohms
All Models 2.0-4.0
(1) Measure resistance between injector terminals.
COLD START INJECTOR TIME SWITCH RESISTANCE SPECIFICATIONS

Terminals Temperature: °F (°C) Ohms
STA-STJ Less Than 59 (15) 25-45
" Greater Than 86 (30) 65-85
STA-Ground N/A 25-85
NOTE: For coolant temperature sensor specifications, see Fig 1.
Fig 1: Coolant Temperature Sensor Specifications
G119427Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
EGR GAS TEMP SENSOR SPECIFICATIONS

Temperature: °F (°C) (1) Ohms
122 (50) 69-89
212 (100) 12-14
302 (150) 3-4
(1) Measure resistance between sensor terminals.
FUEL INJECTOR RESISTANCE SPECIFICATIONS

Application (1) Ohms
Turbo 2.0-3.8
Non-Turbo Approx. 13.8
(1) Measured across terminals at 68°F (20°C).
ISC VALVE RESISTANCE SPECIFICATIONS

Application Ohms
Supra (1) 10-30
(1) Measure resistance between terminals B1 to S1 or S3 or terminals B2 to S2 or S4.
OXYGEN SENSOR HEATER RESISTANCE SPECIFICATIONS

Application Condition Ohms
Turbo (1) 68°F (20°C) 3.0-3.6
(1) Measure resistance between terminals No. 2 and 3.
SUB O2 SENSOR HEATER RESISTANCE SPECIFICATIONS

Application Condition Ohms
Non-Turbo (1) 68°F (20°C) 5.1-6.3
(1) Measure resistance between terminals B+ and HT.
TPS RESISTANCE SPECIFICATIONS

Model/ Application Clearance In. (mm) Terminal Identification Ohmmeter Reading
Non-Turbo VTA & E2 0 (0) 200-1200
" " Fully Open 3500-10,300
" IDL & E2 .016 (.41) 2300 or Less
" " .030 (.76) No Continuity
" VC & E2 N/A 4250-8250
Turbo VTA & E2 0 (0) 200-1200
" " Fully Open 3500-10,300
" IDL & E2 .020 (.51) 2300 or Less
" " .035 (.89) No Continuity
" VC & E2 N/A 4250-8250
TURBO PRESSURE SENSOR SPECIFICATIONS

Vacuum: In. Hg (1) Voltage Drop
3.94 .15-.35
7.87 .40-.60
11.81 .65-.85
15.75 .90-1.10
19.69 1.15-1.35
(1) Voltage drop is from measured voltage of pressure sensor (harness connector terminals VC and E2). Measure voltage between ECU connector terminals PIM and E2. See I - SYS/COMP TESTS article in this section.