Distributor Sensors
DISTRIBUTOR PICK-UP COIL AIR GAP OPERATION
| Application | In. (mm) |
|---|---|
| 4-Cylinder | .008-.016 (.20-.40) |
| V6 | .008-.020 (.20-.51) |
DISTRIBUTOR PICK-UP COIL RESISTANCE - 4-CYLINDER
| Pick-Up Coil Terminals (1) | (2) Ohms | ||||
|---|---|---|---|---|---|
| G+ & G- | 185-265 | ||||
| NE+ & NE- | 370-530 | ||||
|
|||||
DISTRIBUTOR PICK-UP COIL RESISTANCE - V6
| Pick-Up Coil Terminals (1) | (2) Ohms | ||||
|---|---|---|---|---|---|
| G1 & G- | 125-190 | ||||
| G2 & G- | 125-190 | ||||
| NE & G- | 155-240 | ||||
|
|||||