Throttle Position Sensor
TPS RESISTANCE SPECIFICATIONS
| Application | Clearance In. (mm) | Terminal | Ohmmeter Reading |
|---|---|---|---|
| Non-Turbo | 0 (0) | VTA & E2 | 200-1200 |
| " | .016 (.41) | IDL & E2 | 2300 Or Less |
| " | .030 (.76) | IDL & E2 | No Continuity |
| " | Fully Open | VTA & E2 | 3500-10,300 |
| " | " | VC & E2 | 4250-8250 |
| Turbo | 0 (0) | VTA & E2 | 200-1200 |
| " | .020 (.51) | IDL & E2 | 2300 Or Less |
| " | .035 (.89) | IDL & E2 | No Continuity |
| " | Fully Open | VTA & E2 | 3500-10,300 |
| " | " | VC & E2 | 4250-8250 |