NIPPONDENSO STARTER SPECIFICATIONS (DIRECT DRIVE)

Application Specification
Armature
Core Runout .002" (.05 mm)
End Play .002" (.05 mm)
Brush Minimum Length .39" (10 mm)
Brush Spring Minimum Load 2.2 Ft. Lbs. (2.99 N.m)
Commutator
Minimum Diameter 1.10" (27 mm)
Runout .002" (.05 mm)
No-Load Test
Maximum Ampere Draw 50 Amps
Minimum Voltage 11.0 Volts
Minimum RPM 5000 RPM
NIPPONDENSO STARTER SPECIFICATIONS (REDUCTION GEAR)

Application Specification
Armature
Core Runout .002" (.05 mm)
End Play .002" (.05 mm)
Brush Minimum Length .335" (8.5 mm)
Brush Spring Minimum Load 3.9 Ft. Lbs. (5.30 N.m)
Commutator
Minimum Diameter 1.14" (29 mm)
Runout .002" (.05 mm)
No-Load Test
Maximum Ampere Draw 90 Amps
Minimum Voltage 11.5 Volts
Minimum RPM 3000 RPM