Throttle Position Sensor
NOTE:
For terminal identification and testing procedures, see SYSTEM/COMPONENT TESTS
article.
TPS RESISTANCE SPECIFICATIONS
| Application Type | Clearance In. (mm) | Terminals Tested | Ohmmeter Reading | ||||
|---|---|---|---|---|---|---|---|
| Non-Turbo (1) | 0 (0) | VTA & E2 | 340-6300 | ||||
| " | .016 (.41) | IDL & E2 | 500 Or Less | ||||
| " | .024 (.61) | IDL & E2 | No Continuity | ||||
| " | Fully Open | VTA & E2 | 2400-11,200 | ||||
| " | " | VC & E2 | 3100-7200 | ||||
| Turbo (1)(2) | 0 (0) | VTA & E2 | 340-6300 | ||||
| " | .021 (.53) | IDL & E2 | 500 Or Less | ||||
| " | .028 (.71) | IDL & E2 | No Continuity | ||||
| " | Fully Open | VTA & E2 | 2400-11,200 | ||||
| " | " | VC & E2 | 3100-7200 | ||||
|
|||||||