Ignition Timing

IGNITION TIMING (Degrees BTDC @ Idle)

Application (1) (2) Base Timing (3) Advance Timing
Non-Turbo 8-12 7-19
Turbo 8-12 10-20
(1) Check with engine at normal operating temperature, transmission in Neutral, parking brake applied, A/C and all accessories off.
(2) With jumper wire installed between terminals TE1 and E1 on data link connector No. 1.