Instrument Panel: Disassembly
- REMOVE NO. 1 HEATER TO REGISTER DUCT
Remove the 6 screws and No. 1 heater to register duct.
- REMOVE INSTRUMENT PANEL WIRE
- REMOVE NO. 1 SIDE DEFROSTER NOZZLE DUCT
Remove the 2 screws and No. 1 side defroster nozzle duct.
- REMOVE NO. 2 SIDE DEFROSTER NOZZLE DUCT
Remove the 2 screws and No. 2 side defroster nozzle duct.
- REMOVE DEFROSTER NOZZLE
Remove the 3 screws and defroster nozzle.
- REMOVE CENTER BRACKET
Remove the screw and center bracket.
- REMOVE NAVIGATION ANTENNA
Remove the 2 screws and navigation antenna.
- REMOVE NO. 1 PINS
Remove the 2 screws and 2 No. 1 pins.
- REMOVE NO. 1 SAFETY PAD
Remove the 8 screws and No. 1 safety pad.
- REMOVE NO. 2 SAFETY PAD
Remove the 6 screws and No. 2 safety pad.
- REMOVE NO. 1, NO. 2, NO. 3 AND NO. 4 INSTRUMENT PANEL CUSHIONS
- Using a heat light, heat the instrument panel cushions surface to 20 - 30°C (68 - 86°F).
- Remove the instrument panel cushions.
CAUTION: Do not heat the instrument panel cushions and instrument panel excessively.