Starting Service Data

Starter Rated voltage and output power 12 V 1.2 kW, 1.4 kW
No-load characteristics Current 90 A or less at 11.5 V
  rpm 3,000 rpm or more
Brush length STD 15.5 mm (0.610 in.)
  Minimum 8.5 mm (0.335 in.)
Brush spring installed load STD 1.2 kW 13.7 - 19.6 N (1.4 - 2.0 kgf, 3.1 - 4.4 lbf)
  1.4 kW 17.6 - 23.5 N (1.8 - 2.4 kgf, 3.9 - 5.3 lbf)
  Minimum 1.2 kW 9.8 N (1.0 kgf, 2.2 lbf)
  1.4 kW 11.8 N (1.2 kgf, 2.6 lbf)
Commutator    
Diameter STD 30.0 mm (1.181 in.)
  Minimum 29.0 mm (1.142 in.)
Undercut depth STD 0.6 mm (0.024 in.)
  Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Magnetic switch    
Contact plate for wear Maximum 0.9 mm (0.035 in.)