Torque Specification
STARTING SYSTEM COMPONENTS TIGHTENING TORQUE SPECIFICATION
| Part tightened | N.m | kgf.cm | ft.lbf |
|---|---|---|---|
| End cover x Field frame | 1.5 | 15 | 13 in.lbf |
| Starter housing x Magnetic switch | 5.9 | 60 | 52 in.lbf |
| Field frame x Armature assembly | 5.9 | 60 | 52 in.lbf |
| Lead wire x Terminal C of starter | 5.9 | 60 | 52 in.lbf |
| Starter mounting bolt | 39 | 400 | 29 |
| Terminal nut x Terminal C of starter | 17 | 173 | 12 |
| Terminal nut x Terminal 30 of starter | 17 | 173 | 12 |
| Magnetic switch end cover x Magnetic switch housing | 2.5 | 25 | 22 in.lbf |