Fail-Safe Chart
ENGINE COOLANT TEMPERATURE GAUGE:
FAIL-SAFE CHART
| Condition | Response | Recovery |
|---|---|---|
| Engine coolant temperature data is interrupted for 5 seconds. | The gauge needle indicates below "C". | Engine coolant temperature data is received. |
SHIFT INDICATOR:
SHIFT INDICATOR
| Condition | Response | Recovery |
|---|---|---|
| "P to D" data is interrupted for 3 seconds. | All indicator lights go off. | Normal data is received. |
| "S" data is interrupted for 3 seconds. | The "S" indicator light goes off. | Normal data is received. |
GEAR POSITION INDICATOR (1 TO 5):
GEAR POSITION INDICATOR
| Condition | Response | Recovery |
|---|---|---|
| Gear position data is interrupted for 3 seconds or a malfunction signal is received. | The indicator light goes off. | Normal data is received. |
ABS & BRAKE:
GEAR POSITION DATA
| Condition | Response | Recovery |
|---|---|---|
| ABS & Brake data is interrupted for 3 seconds. | The warning light comes on. | Normal data is received. |
DOOR:
ABS BRAKE DATA
| Condition | Response | Recovery |
|---|---|---|
| Regular data is interrupted. | The data received most recently remains indicated. | Normal data is received. |
HEAD (*1)/TAIL (*2):
REGULAR DATA
| Condition | Response | Recovery |
|---|---|---|
| Regular data is interrupted. | The data received most recently remains indicated. | Normal data is received. |
BEAM:
REGULAR DATA
| Condition | Response | Recovery |
|---|---|---|
| Regular data is interrupted. | The indicator light goes off. | Normal data is received. |
KEY:
REGULAR DATA
| Condition | Response | Recovery |
|---|---|---|
| Regular data is interrupted. | The indicator light goes off. | Normal data is received. |
MULTI-INFORMATION (INSTANTANEOUS FUEL CONSUMPTION/POSSIBLE RUNNING DISTANCE):
REGULAR DATA
| Condition | Response | Recovery |
|---|---|---|
| Cruise information data is interrupted for 60 seconds. | The display becomes blank (only measurement units are displayed). | Normal data is received. |
ILLUMINATION:
NORMAL DATA
| Condition | Response | Recovery |
|---|---|---|
| The illumination data is interrupted for 10 seconds or abnormal data is received. | The display remains in daytime mode. | Normal data is received. |
*1: U.S.A. only
*2: Except U.S.A.